Instrumentation
|
|
|
Collihigh Automation manufactures a wide range of low to medium priced instrumentation. These instruments include single channel, multi channel, and microprocessor based units. Instrumentation is manufactured as standard and modified standard units to provide the fastest possible delivery. It offers a wide range of inline amplifiers to be used with transducers and transmitters made by Collihigh or other manufacturers.
These industrially rugged, highly reliable instruments come in table top, panel mount, and rack mounted configurations and are suitable for lab or shop floor use. Most models come with a 4 1/2 digit LED display, 20,000 count resolution, 5V or 10V transducer excitation supply, and +/- 5VDC output. Shunt calibration (R-cal) also comes standard on most models. A wide range of optional features such as zero track and tare, transducer linearization, high/low limits, peak detector, track and hold, and a 4-20mA output are also offered. |
CH6 - Single Channel Instrumentation
| Input |
volts, direct current, variable resitor, thermocouple or RTD |
| Accuracy |
±0.5%, ±0.2% |
| Output |
4-20mA, 0-10VDC, RS-232/485 or Relay Output, mini-printer. |
|
KSB - Weighing Instrumentation
| Input |
Weighing sensor |
| Accuracy |
±0.05%F.S |
| Output |
RS-232/485 or BCD code. |
|
KSC - PID Control Instrumentation
| Input |
volts, direct current, variable resitor, thermocouple or RTD. |
| Accuracy |
±0.2% |
| Output |
4-20mA, 0-10VDC, RS-232/485 , Relay Output, Siliconcontrolled rectifier, power output. |
|
KSD - Multi-Channel Instrumentation
| Input |
volts d.c., direct current, thermocouple, RTD or mv signal. |
| Accuracy |
±0.2% |
| Output |
4-20mA, 0-10VDC, RS-232/485 or Relay Output, mini-printer. |
|
KSJ - Flux Integral Instrumentation
| Input |
Flux Sensor with volts d.c., direct current or Pulse output. It also can connect compensatory RTD and pressure sensors. |
| Accuracy |
±0.2% |
| Output |
4-20mA, 0-10VDC, RS-232/485 or Relay Output, mini-printer. |
|
KSM - Rotate speed, Line spped or frequency Instrumentation
| Input |
volts d.c.pulse (PNP,NPN) , or MV Pulse. |
| Accuracy |
±0.02% |
| Output |
4-20mA, 0-10VDC, RS-232/485 or mini-printer. |
|
KSR - Recorder Instrumentation with TFT 5' Display
| Input |
Free inputs, volts d.c., direct current, thermocouple, RTD |
| Accuracy |
±0.02% |
| Output |
4-20mA, 0-10VDC, RS-232/485 or mini-printer. |
|
|
|
|